Classification
Articles
產(chǎn)品展示/ Product display
γ-氨基丁酸A受體α4(gABRa4)重組蛋白γ-氨基丁酸(GABA)是哺乳動物大腦中主要的抑制性神經(jīng)遞質(zhì),它作用于GABA-A受體,即配體門控的氯離子通道。這些通道的氯電導可以通過與GABA-A受體結(jié)合的苯二氮卓類藥物來調(diào)節(jié)。已經(jīng)鑒定出至少16種不同的GABA-A受體亞基。該基因編碼亞基α-4,該亞基參與自閉癥的病因,并最終通過與另一個亞基γ-氨基丁酸受體β-1(GABRB1)的相互作用增加自閉
聯(lián)系電話:15221858802
品牌 | 信裕生物 | CAS | 詳見說明書 |
---|---|---|---|
分子式 | 詳見說明書 | 純度 | > 90% |
分子量 | 55.8kDa | 貨號 | XY92073RPHu |
規(guī)格 | 50µg/100µg | 供貨周期 | 一周 |
主要用途 | SDS-PAGE; WB | 應用領域 | 生物產(chǎn)業(yè) |
Recombinant Gamma-Aminobutyric Acid A Receptor Alpha 4 (gABRa4)
γ-氨基丁酸A受體α4(gABRa4)重組蛋白
[ PROPERTIES ]
Source: Prokaryotic expression
Host: E.coli
Residues: Gln36~Tyr258
Tags: N-terminal His and GST Tag
Subcellular Location: Membrane
Purity: > 90%
Traits: Freeze-dried powder
Buffer formulation: PBS, pH7.4, containing 0.01% SKL, 5% Trehalose.
Original Concentration: 200µg/mL
Applications: Positive Control; Immunogen; SDS-PAGE; WB.
(May be suitable for use in other assays to be determined by the end user.)
Predicted isoelectric point: 8.6
Predicted Molecular Mass: 55.8kDa
Accurate Molecular Mass: 66kDa as determined by SDS-PAGE reducing conditions.
Phenomenon explanation:
The possible reasons that the actual band size differs from the predicted are as follows:
1.Splice variants: Alternative splicing may create different sized proteins from the same gene.
2. Relative charge: The composition of amino acids may affects the charge of the protein.
3. Post-translational modification: Phosphorylation, glycosylation, methylation etc.
4. Post-translation cleavage: Many proteins are synthesized as pro-proteins, and then cleavedto give the active form.
5. Polymerization of the target protein: Dimerization, multimerization etc.
[ USAGE ]
Reconstitute in 10mM PBS (pH7.4) to a concentration of 0.1-1.0 mg/mL. Do not vortex.
[ STORAGE AND STABILITY ]
Storage: Avoid repeated freeze/thaw cycles.
Store at 2-8oC for one month.
Aliquot and store at -80oC for 12 months.
Stability Test: The thermal stability is described by the loss rate. The loss rate was determined by accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and no obvious degradation and precipitation were observed. The loss rate is less than 5% within the expiration date under appropriate storage condition.
[SEQUENCE ]
[ IDENTIFICATION ]
[ IMPORTANT NOTE ]
The kit is designed for research use only, we will not be responsible for any issue if the kit was used in clinical diagnostic or any other procedures.
特別提示:本公司的所有產(chǎn)品僅可用于科研實驗,嚴禁用于臨床醫(yī)療及其他非科研用途!以實際收貨產(chǎn)品說明書為準,網(wǎng)站說明書僅供參考!
電話