Classification
Articles
產(chǎn)品展示/ Product display
HTN1抗原;唾液富組蛋白1重組蛋白多種屬 Histatin 1是一種富含組氨酸的磷蛋白,存在于人腮腺唾液中,具有念珠菌酸活性,通過吸附羥基磷灰石在礦化中發(fā)揮作用。組胺1的磷酸化有助于其結(jié)合羥基磷灰石的能力。唾液組胺是一個富含組氨酸的小肽家族,具有強大的抗真菌活性。下頜下和舌下組胺分泌水平可能會影響口腔中酵母的狀態(tài)。因此,組胺被認為是治療口腔念珠菌病的潛在藥物。
聯(lián)系電話:15221858802
品牌 | 信裕生物 | CAS | 詳見說明書 |
---|---|---|---|
分子式 | 詳見說明書 | 純度 | > 95% |
分子量 | 11.5kDa | 貨號 | XY92433RPHu |
規(guī)格 | 50µg/100µg | 供貨周期 | 一周 |
主要用途 | SDS-PAGE; WB | 應用領(lǐng)域 | 生物產(chǎn)業(yè) |
Recombinant Histatin 1 (HTN1)
唾液富組蛋白1(HTN1)重組蛋白
[ PROPERTIES ]
Source:Prokaryotic expression
Host: E.coli
Residues:Asp20~Asn57
Tags:N-terminal His Tag
Subcellular Location: Secreted
Purity: > 95%
Traits:Freeze-dried powder
Buffer formulation: 20mM Tris, 150mM NaCl, pH8.0, containing 0.01% skl, 5%Trehalose.
Original Concentration:50µg/mL
Applications:Positive Control; Immunogen; SDS-PAGE; WB.
(May be suitable for use in other assays to be determined by the end user.)
Predicted isoelectric point:6.4
Predicted Molecular Mass:11.5kDa
Accurate Molecular Mass:15kDa as determined by SDS-PAGE reducing conditions.
Phenomenon explanation:
The possible reasons that the actual band size differs from the predicted are as follows:
1.Splice variants: Alternative splicing may create different sized proteins from the same gene.
2. Relative charge: The composition of amino acids may affects the charge of the protein.
3. Post-translational modification: Phosphorylation, glycosylation, methylation etc.
4. Post-translation cleavage: Many proteins are synthesized as pro-proteins, and then cleavedto give the active form.
5. Polymerization of the target protein: Dimerization, multimerization etc.
[ USAGE ]
Reconstitute in ddH2O to a concentration of 0.1-0.5 mg/mL. Do not vortex.
[ STORAGE AND STABILITY ]
Storage: Avoid repeated freeze/thaw cycles.
Store at 2-8oC for one month.
Aliquot and store at -80oC for 12 months.
Stability Test: The thermal stability is described by the loss rate. The loss rate was determined by accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and no obvious degradation and precipitation were observed. The loss rate is less than 5% within the expiration date under appropriate storage condition.
[SEQUENCE ]
[ IDENTIFICATION ]
[ IMPORTANT NOTE ]
The kit is designed for research use only, we will not be responsible for any issue if the kit was used in clinical diagnostic or any other procedures.
特別提示:本公司的所有產(chǎn)品僅可用于科研實驗,嚴禁用于臨床醫(yī)療及其他非科研用途!以實際收貨產(chǎn)品說明書為準,網(wǎng)站說明書僅供參考!
電話